RJCP.SerialPortStream 3.0.1

dotnet add package RJCP.SerialPortStream --version 3.0.1                
NuGet\Install-Package RJCP.SerialPortStream -Version 3.0.1                
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="RJCP.SerialPortStream" Version="3.0.1" />                
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add RJCP.SerialPortStream --version 3.0.1                
#r "nuget: RJCP.SerialPortStream, 3.0.1"                
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install RJCP.SerialPortStream as a Cake Addin
#addin nuget:?package=RJCP.SerialPortStream&version=3.0.1

// Install RJCP.SerialPortStream as a Cake Tool
#tool nuget:?package=RJCP.SerialPortStream&version=3.0.1                

Serial Port Stream

SerialPortStream is an independent implementation of System.IO.Ports.SerialPort and SerialStream for better reliability and maintainability, and now for portability to Mono on Linux systems.

The SerialPortStream is a ground up implementation of a Stream that buffers data to and from a serial port. It uses low level Win32API (on Windows) for managing events and asynchronous I/O, using a programming model as in the MSDN PipeServer example.

On Linux, it uses a support library to interface with Posix OS calls for an event loop.

These notes are for version 3.x, which is a refactoring of v2.x for better maintainability. See the end of these notes for differences.

  • 1.0 Why another Serial Port implementation
  • 2.0 Goals
    • 2.1 Issues with MS Serial Port
    • 2.2 Differences to the MS Serial Port
  • 3.0 System Requirements
    • 3.1 Testing
    • 3.2 Compatibility
      • 3.2.1 .NET Frameworks (Windows)
      • 3.2.2 Mono Framework (Linux Only)
  • 4.0 Installation
    • 4.1 Windows
    • 4.2 Linux
  • 5.0 Extra Features
    • 5.1 Reading and Writing - Buffering
  • 6.0 Developer Notes
    • 6.1 Logging
      • 6.1.1 The LogSource abstraction
      • 6.1.2 .NET Framework (.NET 4.0 to .NET 4.8)
      • 6.1.3 .NET Core
        • 6.1.3.1 Dependency Injection
        • 6.1.3.2 Singleton via LogSource
  • 7.0 Known Issues
    • 7.1 General Issues
      • 7.1.1 ReadTo
    • 7.2 Windows
      • 7.2.1 Driver Specific Issues on Windows
        • 7.2.1.1 Flow Control
        • 7.2.1.2 BytesToWrite
    • 7.3 Linux
      • 7.3.1 Mono on non-Windows Platforms
      • 7.3.2 Driver Specific Issues on Linux
        • 7.3.2.1 Parity Errors
        • 7.3.2.2 Garbage Data on Open
        • 7.3.2.3 Monitoring Pins and Timing Resolution
        • 7.3.2.4 Close Times with Flow Control
        • 7.3.2.5 Opening Ports (and some unit test case failures)
    • 7.4 Guidelines on Serial Protocols

1.0 Why another Serial Port implementation

Microsoft and Mono already provided a reasonable implementation for accessing the serial port. Today the main goal is to provide a buffered solution that can be used on various operating systems, the the ability to also abstract hardware. Along the way, various issues with the original implementation in .NET Framework are resolved in this library (see the next section).

2.0 Goals

This project tries to achieve the following:

  • An implementation similar to the MS implementation of SerialPort. It's not meant to be 100% compatible, but instead provide similar functionality
  • Abstract the driver implementation and provide for a more reliable transport, by making writing serial data completely buffered. With the MS implementation, one can write data, but subsequently needs to check if all data is written or not. If it isn't written, then it needs to be retried. The SerialPortStream makes this easier.
  • Provide for reliable and consistent behaviour. See the next section.

2.1 Issues with MS Serial Port

The SerialPortStream tries to solve the following issues observed:

  • Zach Saw describes issues regarding behaviour of the fAbortError flag in the Serial DCB. The SerialPortStream defines this flag.
  • Closing a serial port, then reopening it generally causes problems. The SerialPortStream shouldn't have this issue. Note, there are some cases observed where the Operating System hangs, and this can't be avoided.
  • The ReadTo() implementation can subtly change the byte stream buffer, when one switches from characters to bytes. This problem occurs because the MS implementation actually converts the characters back to bytes into its buffer. So if you have UTF8, decoded some invalid characters and then have a timeout, this results in the invalid characters being converted back to bytes, resulting in "lost" data. I take some care when decoding bytes to characters to ensure a seamless and accurate transition between bytes and characters.
  • Write() gives the data to the serial port. If the operation is asynchronous, the call back results in the number of bytes that were actually transferred to the driver. You need to check yourself if this is valid or not. In the synchronous case, the data is simply thrown away. The SerialPortStream method simply copies data to a local buffer and uses asynchronous writes in a different thread. It works in the background to send out the data you provided. If the data can't be sent, then you get a TimeoutException without any data being buffered at all. So you can implement reliable protocols and your code is simpler.
  • Disposing or Closing the serial port during a blocking write operation will not abort the write operation. This implementation will abort with an System.IO.IOException type.

2.2 Differences to the MS Serial Port

The goal is to provide a Stream, not an API compatible replacement to the SerialPort.

All data is buffered internally in memory, captured using an I/O thread. The extra buffering adds delays by reading the bytes, then performing a context switch for the user code to read the buffer. This can slow down your software.

Buffering solves the problem however, that data is read from the serial port in an arbitrary sized memory buffer, and not dependent on the driver, so a likelihood of driver underruns and overruns are reduced. This was an important aspect when writing this library.

3.0 System Requirements

3.1 Testing

Software has been tested and developed using:

  • .NET Standard 2.1 on Windows 10 Pro x64, .NET SDK 5.x
  • .NET 4.8 on Windows 10 Pro x64
  • Mono 6.x from Xamarin on Ubuntu 20.04 (64-bit)

See later in these notes for known issues and changes.

3.2 Compatibility

3.2.1 .NET Frameworks (Windows)

The software is written originally for .NET 4.0 and should work on those platforms. It is extended for .NET 4.5 features. A version targets .NET Core with API level .NET Standard 2.1, so should work on .NET Core 2.1, 3.1 and .NET 5.0 and later.

Windows XP SP3 and later should work when using .NET 4.0. It's not possible to run the unit tests on Windows XP since the unit tests have migrated to NUnit 3.x, but was working fine prior to that with NUnit 2.x.

3.2.2 Mono Framework (Linux Only)

The SerialPortStream should work on Linux, and it should be possible to import the assembly into your code when running on Linux.

When using the Mono Framework, you should reference the .NET 4.0 or .NET 4.5 projects.

It has been tested to compile and unit test cases pass with the dotnet command on Linux.

4.0 Installation

4.1 Windows

On Windows, just reference the assembly in your project installing the NuGet version.

4.2 Linux

You first need to compile the support library libnserial.so for your platform. To do that, you'll need a compiler (e.g. GCC 4.8 or later) and cmake. The binaries for Linux are not part of the distribution, as it's operating system specific.

After cloning the repository, execute the following:

git clone https://github.com/jcurl/serialportstream.git
cd serialportstream/dll/serialunix
./build.sh

Binaries are built and put in the bin folder from where you ran the build script. You can add a reference to LD_LIBRARY_PATH to the library:

export LD_LIBRARY_PATH=`pwd`/bin/usr/local/lib:$LD_LIBRARY_PATH

and then run your Mono program from there.

Or you can build and install in your system:

cd serialportstream/dll/serialunix
mkdir mybuild
cd mybuild
cmake .. && make
sudo make install

5.0 Extra Features

The following features are in addition to the System.IO.Ports.SerialPort implementation:

  • You can obtain the RingIndicator pin status.
  • The Read() and Write() buffers are completely independent of the low level Windows driver.
    • For those concerned, the buffering means that a copy must always be made on every Read() and Write() method.

5.1 Reading and Writing - Buffering

Why is it interesting to perform buffering? A driver might be configured to be 4096 or 8192 bytes (which is quite typical). Testing with the PL2303 chipset, one can't write more than about 12KB with a single write operation.

A Write buffer may be 128KB, which one writes to. The thread in the background will write the data and issue as many write calls as is necessary to get the job done. A Read buffer may be 5MB. The background thread will read from the serial port when ever data arrives and buffers into the 5MB.

So long as the I/O thread in .NET can execute every 100-200ms, it can continue to read data from the driver. Your own application doesn't need to keep to such difficult time constraints. Such issues typically arise in Automation type environments where a computer has many different peripherals. So long as the process doesn't block, your main application might sleep for 10 seconds and you've still lost no data. The MS implementation wouldn't be so simple, you have to make sure that you perform frequent read operations else the driver itself might overflow (resulting in lost data).

6.0 Developer Notes

6.1 Logging

If you come across a problem using this library, you may be asked to provide additional debug logs. This section describes how to obtain those logs for .NET Framework and .NET Core.

6.1.1 The LogSource abstraction

Logging for SerialPortStream 3.x uses my RJCP.Diagnostics.Trace library that provides an implementation called LogSource. This is a wrapper around TraceSource, and can provide where necessary a TraceListener for .NET Core. For .NET Core, it provides a factory method as a singleton as an alternative to dependency injection. The following sections provide more details.

6.1.2 .NET Framework (.NET 4.0 to .NET 4.8)

The library uses the TraceSource object, so you can add tracing to your project in the normal way. You should use the switch name RJCPIO.Ports.SerialPortStream. An example of an app.config file that you can use to enable logging:

<?xml version="1.0" encoding="utf-8" ?>
<configuration>
  <system.diagnostics>
    <sources>
      <source name="RJCP.IO.Ports.SerialPortStream" switchValue="Verbose">
        <listeners>
          <clear/>
          <add name="myListener"/>
        </listeners>
      </source>
    </sources>
    <sharedListeners>
      <add name="myListener" type="System.Diagnostics.TextWriterTraceListener" initializeData="logfile.txt"/>
    </sharedListeners>
  </system.diagnostics>
</configuration>

Please note, for SerialPortStream 3.x and later, the name of the trace source has changed to include the full namespace, to be compatible with my other projects.

6.1.3 .NET Core

.NET Core has an implementation of TraceListener and TraceSource, but it doesn't load the app.config on start up, nor provide a singleton for applications to use for tracing. There are two ways to enable logging for SerialPortStream on .NET Core.

6.1.3.1 Dependency Injection

The SerialPortStream has a constructor where you can provide your ILogger object for tracing.

Internally, the ILogger is wrapped around a minimal TraceListener implementation to keep the code common between .NET Framework and .NET Core.

6.1.3.2 Singleton via LogSource

When upgrading from .NET Framework to .NET Core, it can be quite difficult to refactor software from using a singleton pattern, to dependency injection, and may require large swaths of code to be refactored.

To avoid this, the LogSource classes provide a mechanism to get an ILogger using a factory method you provide.

You may add in your code the following:

using Microsoft.Extensions.Logging;
using RJCP.CodeQuality.NUnitExtensions.Trace;
using RJCP.Diagnostics.Trace;

internal static class GlobalLogger
{
  static GlobalLogger() {
    ILoggerFactory factory = LoggerFactory.Create(builder => {
      builder
        .AddFilter("Microsoft", LogLevel.Warning)
        .AddFilter("System", LogLevel.Warning)
        .AddFilter("RJCP", LogLevel.Debug)
        .AddNUnitLogger();
      });
    LogSource.SetLoggerFactory(factory);
  }

  public static void Initialize() {
    /* Intentially empty. By calling this method, the static constructor
       will be automatically called */
  }
}

The example above is from the unit test cases for SerialPortStream, but can be easily adapted for your own projects. The important part is that:

  • In your production code, you assign the static factory with LogSource.SetLoggerFactory(), which is not called as part of your unit tests. It will likely be different to the example given above, as you'd want to instead, get the logging configuration (log levels) via a configuration file.
  • Your test code would set the LogSource.SetLoggerFactory() similarly as in the example provided above (the example given above is good for NUnit 3.x with the .AddNUnitLogger() provided by my RJCP.CodeQuality library).
  • Setting the factory is only needed for .NET Core. On .NET Framework, the TraceSource class provides the singleton functionality and will instantiate for you the correct TraceSource from the application configuration file.

The code works by requesting to the ILoggerFactory.CreateLogger with the name RJCP.IO.Ports.SerialPortStream. This is also the motivation why the trace source was changed to include the full namespace. The code above shows that it will create this object and log all debug level events to the NUnit logger.

7.0 Known Issues

7.1 General Issues

7.1.1 ReadTo

The implementation of ReadTo and other character based read events with the SerialPortStream is slow. It tries to calculate the size (in bytes) of each individual character, in case the user decides to read bytes in-between. The purpose of this was to prevent possible data loss in when a read of bytes is mixed with a read of characters. It's recommended not to use the character based APIs.

Some test cases are failing and needs to be investigated (although it's not clear if this is a bug in the library or in the test case).

7.2 Windows

The following issues are known:

  • This is not an issue in the library, but when using the Com0Com for running unit tests, some specific test cases for Parity will fail. That is because Com0Com doesn't emulate data at a bit level. Using real serial hardware with a NULL modem adapter works as expected.
  • .NET 4.0 to .NET 4.8 and .NET Core has a minor issue in System.Text.Decoder that in a special circumstance it will consume too many bytes. The PeekChar() method is therefore a slower implementation than what it could be. Please refer to the Xamarin bug 40002. Found against Mono 4.2.3.4 and later tested to be present since .NET 4.0 on Windows XP also.
7.2.1 Driver Specific Issues on Windows
7.2.1.1 Flow Control

Using the FTDI chipset on Windows 10 x64 (FTDI 2.12.16.0 dated 09/Mar/2016) flow control (RTS/CTS) doesn't work as expected. For writing small amounts of data (1024 bytes) with CTS off, the FTDI driver will still send data. See the test case ClosedWhenFlushBlocked, change the buffer from 8192 bytes to 1024 and the test case now fails. This problem is not observable with com0com 3.0. You can see the effect in logs, there is a TX-EMPTY event that occurs, which should never be there if no data is ever sent.

7.2.1.2 BytesToWrite

On Windows, the SerialPortStream returns the bigger of either the internal write buffer, or the amount of data in the output queue of the driver. Drivers don't report the number of bytes that are in the output queue before the next write begins, and may return sooner. This leads to the effects:

CP2101 Driver

This driver indicates more bytes are in the output queue than what it will return from the current ongoing write operation. This can cause some jumps in the returned value.

CP210x Universal Windows Driver v10.1.10 1/13/2021.

For example:

BytesToWrite = 40960 (driver 12288)
RJCP.IO.Ports.SerialPortStream Verbose: 0 : COM5: SerialThread: ProcessWriteEvent: 1024 bytes
BytesToWrite = 40412 (driver 40412)
RJCP.IO.Ports.SerialPortStream Verbose: 0 : COM5: SerialThread: DoWriteEvent: WriteFile(736, 312385272, 39936, ...) == False
BytesToWrite = 40387 (driver 40387)
BytesToWrite = 40386 (driver 40386)

The internal buffer is 40kB, the driver returned it wrote 1024 bytes, but the queue still has 40412 bytes (which is more than the 39936 bytes it should be).

It can also fluctuate without writes without calls to the OS in between.

BytesToWrite = 40418 (driver 40418)
BytesToWrite = 40393 (driver 40393)
BytesToWrite = 40392 (driver 40392)
BytesToWrite = 40391 (driver 40391)
BytesToWrite = 40390 (driver 40390)
BytesToWrite = 40389 (driver 40389)
BytesToWrite = 40428 (driver 40428)
BytesToWrite = 40427 (driver 40427)
BytesToWrite = 40426 (driver 40426)
PL2303 RA

Generally this driver reports that it has zero bytes in the output queue, but may sometimes report the number of bytes in the last WriteFile() call. This is not a problem, but the number of bytes in the output queue is less than what is still to be written, so a user may think it is complete, when it is not.

7.3 Linux

The SerialPortStream was tested on Ubuntu 14.04 to 20.04. Feedback welcome for other distributions!

The main functionality on Linux is provided by a support C library that abstracts the Posix system call select().

Issues in the current implementation are:

  • Custom baud rates are not supported. To know what baud rates are supported on your system, look at the file config.h after building.
  • DSR and DTR handshaking is not supported. You can still set and clear the pins though.

Patches are welcome to implement these features!

7.3.1 Mono on non-Windows Platforms

Use the currently supported versions of Mono provided by the Mono project for your Linux distribution. For example, Ubuntu 14.04 ships with Mono 3.2.8 which is known to not work.

  • [Mono-Dev] Mono 3.2.8 incompatibility with .NET 4.0 on Windows 7-10. The System.Text implementation for converting bytes to UTF8 don't work. If you don't use the character based methods, it may work. But the software has not been tested against this framework.
  • The DataReceived event doesn't fire for the EOF character (0x1A). On Windows it does, as this is managed by the driver itself and not emulated by the C-Library.
  • Linux doesn't implement DSR.
7.3.2 Driver Specific Issues on Linux

Tests have been done using FTDO, PL2303H, PL2303RA and 16550A (some still do exist!). The following has been observed:

7.3.2.1 Parity Errors

Some chipsets do not report properly parity errors. The 16550A chipset works as expected. Issues observed with FTDI, PL2303H, PL2303RA. In particular, on a parity error, more bytes are reported as having parity errors than there are in the stream. Tested using loopback devices with comptest.

$ ./nserialcomptest /dev/ttyUSB0 /dev/ttyUSB1`
  [ RUN      ] SerialParityTest.Parity7E1ReceiveError
/home/jcurl/Programming/serialportstream/dll/serialunix/libnserial/comptest/SerialParityTest.cpp:221: Failure
Value of: comparison
  Actual: false
Expected: true
Unexpected byte received with Even Parity
[  FAILED  ] SerialParityTest.Parity7E1ReceiveError (585 ms)
[ RUN      ] SerialParityTest.Parity7O1ReceiveError
/home/jcurl/Programming/serialportstream/dll/serialunix/libnserial/comptest/SerialParityTest.cpp:373: Failure
Value of: comparison
  Actual: false
Expected: true
Unexpected byte received with Even Parity
[  FAILED  ] SerialParityTest.Parity7O1ReceiveError (584 ms)
[ RUN      ] SerialParityTest.Parity7O1ReceiveErrorWithReplace
/home/jcurl/Programming/serialportstream/dll/serialunix/libnserial/comptest/SerialParityTest.cpp:427: Failure
Value of: comparison
  Actual: false
Expected: true
Unexpected byte received with Even Parity
[  FAILED  ] SerialParityTest.Parity7O1ReceiveErrorWithReplace (572 ms)
7.3.2.2 Garbage Data on Open

On Linux Kernel with Ubuntu 14.04 and Ubuntu 16.04, we observe that some USB-SER drivers provide extra data depending on what a previous process was doing. It shows itself as garbage zero's appearing at the beginning of a stream when reading, and may be visible in your application also. There's a test case comptest/kernelbug that shows this behaviour on a Lenovo T61p. Affected is PL2303H and FTDI chipsets. Chipsets that don't show this behaviour are 16550A and PL2303RA chipsets. Invocate the test program twice and you'll see the error. This is reported to Ubuntu

$ kernelbug /dev/ttyUSB0 /dev/ttyUSB1
Offset: 4
Flushing...
Writing Complete...
Reading complete...
Comparison MATCH                    <---- PASS
Flushing...
Reading complete...
Complete...

$ kernelbug /dev/ttyUSB0 /dev/ttyUSB1
Offset: 108
Flushing...
Flush 2 bytes
Writing Complete...
Reading complete...
ERROR: Comparison mismatch          <---- ERROR
Flushing...
Flush 510 bytes
Reading complete...
Complete...
7.3.2.3 Monitoring Pins and Timing Resolution

Monitoring of pins CTS, DSR, RI and DCD is not 100% reliable for some chipsets and workarounds are in place. In particular, the chips PL2303H, PL2303RA do not support the ioctl(TIOCGICOUNT), so on a pin toggle, we cannot reliably detect if they have changed if the pulse is too short. For 16550A and FTDI chips, this ioctl() does work and so we can always detect a change. To check if your driver supports the ioctl(TIOCGICOUNT) call, run the small test program comptest/icount.

$ ./icount /dev/ttyS0
Your driver supports TIOCGICOUNT
ocounter.cts=0
ocounter.dsr=0
ocounter.rng=3
ocounter.dcd=0

or in the case it's not supported:

$ ./icount /dev/ttyUSB0
Your driver doesn't support TIOCGICOUNT
  Error: 25 (Inappropriate ioctl for device)
7.3.2.4 Close Times with Flow Control

Some times closing the serial port may take a long time (observed from 5s to 21s) if it is write blocked due to hardware flow control. In particular, the C-library function serial_close() appears to take an excessive time when calling close(handle->fd) on Ubuntu 16.04. This issue appears related to the Linux driver and not the MONO framework.

The .NET Test Cases that show this behaviour are (blocking on write):

  • ClosedWhenBlocked
  • CloseWhenFlushBlocked
  • DisposeWhenBlocked
  • DisposeWhenFlushBlocked

This issue is not reproducible with the 16550A UART when it is write blocked. In this case, the times for closing are usually not more than 20ms.

7.3.2.5 Opening Ports (and some unit test case failures)

When testing continuously to open a port, send data, and then receive on another port using a NULL-modem cable, minor issues can occur that result in test case failures. These issues would also be visible in real-world programs and are driver dependent.

The test scenario is on Linux (Ubuntu 20.04) with various USB serial port devices. The test case ReadToWithMbcs from SerialPortStreamNativeTest is modified to run 2000 times with [Repeat(2000)]. The command to run the test after building is then:

dotnet test RJCP.SerialPortStreamNativeTest.dll --filter Name=ReadToWithMbcs

(please note, not only this test case is affected, but it is easy to reproduce.)

  • FTDI: After opening the serial port, in about 1% of the cases, data is not sent (observed using .NET Mono 4.0 and 4.5). It is confirmed that the system call write() was called, and all data was given to the kernel via the library libnserial. However, on the other serial port, data is never received. Waiting 15ms after opening would resolve the problem - this workaround will not be part of the SerialPortStream as it appears to be very specific to this driver and similar behaviour is not observed on other drivers.
  • PL2303H: Sometimes on connecting the serial port, a spurios 0xFF is sent. This causes the test case to fail, as data that was not sent is received and affects the output.
  • PL2303RA: The test cases appear to run about 10x slower than any other driver, but no errors were observed.
  • CP2101: Seems to work flawlessly.

7.4 Guidelines on Serial Protocols

Given the issues listed in this section, one can come up with the following recommendations for protocol design over the serial port:

  • Assume that at Layer 2 (the serial port bus), data can be inserted, modified, or deleted.
  • Define data as frames. There should be a marker byte indicating the start of a frame, a length to know how much data should be received, and a checksum (at least a CRC16) that can be used to check the integrity of the frame.
  • Define the protocol to be able to resend data in case of lost data if needed, or can continue if data is lost.

I recommend to not use hardware or software flow control, but define in the serial protocol frames, like a link control protocol (LCP) that can manage this. Do not use parity, and instead opt to use checksum bytes within a frame.

  • Hardware flow control can lead to deadlocks in software. No flow control just means data can be lost, and can be replaced using a LCP. Software flow control can also cause complications in the protocol, which can be more generically handled using a LCP.
  • Parity can insert arbitrary bytes and corrupted data, especially with USB serial devices. Use frame checksums (FCS) instead.

Allow bundling of frames one after the other, and decode separately. Lots of small frames that need to be acknowledged can lead to delays between frames, and longer transmission times for an already "slow" bus speed. The SerialPortStream is buffered, so performance is impacted by lots of context switches between sending data, and waiting for a response, as there is a buffer thread used in-between.

Product Compatible and additional computed target framework versions.
.NET net6.0 is compatible.  net6.0-android was computed.  net6.0-ios was computed.  net6.0-maccatalyst was computed.  net6.0-macos was computed.  net6.0-tvos was computed.  net6.0-windows was computed.  net7.0 was computed.  net7.0-android was computed.  net7.0-ios was computed.  net7.0-maccatalyst was computed.  net7.0-macos was computed.  net7.0-tvos was computed.  net7.0-windows was computed.  net8.0 is compatible.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed. 
.NET Framework net40 is compatible.  net403 was computed.  net45 was computed.  net451 was computed.  net452 was computed.  net46 was computed.  net461 was computed.  net462 is compatible.  net463 was computed.  net47 was computed.  net471 was computed.  net472 was computed.  net48 was computed.  net481 was computed. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages (1)

Showing the top 1 NuGet packages that depend on RJCP.SerialPortStream:

Package Downloads
RJCP.SerialPortStream.Virtual

An independent implementation of System.IO.Ports.SerialPort and SerialStream for better reliability and maintainability. Provides methods to support testing with a virtual native serial port instance.

GitHub repositories (1)

Showing the top 1 popular GitHub repositories that depend on RJCP.SerialPortStream:

Repository Stars
AbkarinoMHM/PS4SysconTools
PS4 Syscon Tools is a free solution that allow you to manipulate original PlayStation 4 Syscon chip (Renesas RL78/G13).
Version Downloads Last updated
3.0.1 14,457 3/9/2024
3.0.0 1,752 6/9/2023